C-1500N Wall Mount | Chem-Feed®
|
|
|

Mounting Location
-
Choose an area located near the chemical supply tank,
chemical injection point and electrical supply. Although the pump is
designed to withstand outdoor conditions, a cool, dry, well ventilated
location is recommended. Install the pump where it can be easily
serviced.
-
Mount the pump to a secure surface or wall using the
enclosed hardware. Wall mount to a solid surface only. Mounting to
drywall with anchors is not recommended.
-
Do not mount the pump directly over your chemical
container. Chemical fumes may damage the unit. Mount the pump off to the
side or at a lower level than the chemical container opening.
-
Mounting the pump lower than the chemical container will
gravity feed the chemical into the pump. This "flooded suction"
installation can reduce the time required to prime the pump. Install a
shut-off valve, pinch clamp or other means to halt the gravity feed to
the pump during servicing.
-
Your solution tank should be sturdy. Keep the tank covered
to reduce fumes.
-
Be sure your installation does not constitute a cross
connection with the drinking water supply. Check your local plumbing
codes.
|
|
|
Can't find what you're looking for?
Tell us what it is so we can add it to our website. |
|
Caution:
Always wear protective clothing, face shield, safety glasses and gloves when
working on or near your metering pump.
Additional precautions should be taken depending on the solution being
pumped. Refer to MSDS precautions from your solution supplier. |
|
Note: All
diagrams are strictly for guideline purposes only. Always consult an
expert before installing the Chem-Feed/FlexFlo pump on specialized systems.
The Chem-Feed/FlexFlo should be serviced by qualified persons only. |
|
|